Product Details:
Minimum Order Quantity | 1 Unit |
Power input | 200 VA |
Power supply | 230 V +- 10%, 50 Hz |
Remote inputs | RS-232 |
Brand | Athena |
Model | 10ml |
Display Inch | LED |
Application | Laboratory Use |
Specification:
HPLC Column Washing Pumps LCP - 02 (Series II):
Pump Details:
Specification:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model | HPLC 10 |
Brand | Athena |
Display Inch | LCD |
Application | Laboratory Use |
Size | 0-10ml |
Temperature Zone | 6000psig |
SPECIFICATIONS
Hydraulic system | Dual piston in series pump, main & auxiliary |
Pump head | 10ml stainless steel /PEEK analytical 50 ml stainless steel /PEEK semi-preparative |
Maximum working pressure | 10ml pump head 42Mpa for stainless steel /30Mpa for PEEK 50ml pump head 30Mpa for stainless steel /20Mpa for PEEK |
Flow Range | 10ml pump head 0.001-9.999ml/min 50ml pump head 0.001-49.99ml/min |
Flow rate accuracy | ±0.5% measurement at 1ml/min |
Flow rate precision | RSD≤0.1% measurement at 1ml/min |
Display | 320 X 240 blue background color |
Protection | Adjustive Pmax & Pmin, the pump stop automatically when the pressure higher than Pmax or lower than Pmin for 2 minutes, meanwhile the data will be automatically saved |
System connection | 1/16”capillaries |
Control | Stand-alone mode by front keypad HPG Mode: one pump work as master, others work as slave CXTH control software(e.g. CXTH3000,Clarity etc. ) |
Communications | RS-232 |
Power supply | AC220V±10%,50Hz,400W |
Dimensions and weight | 410 X 270 X 180mm(LX W X H) 14Kg |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | Flow Chemistry |
Brand | Athena |
Usage/Application | Laboratory Use |
Display Inch | 2 x 2 |
Size | 1/16 |
Temperature Zone | normal |
Capacity | Flow range 0.1 to 50.0 mL / min |
Product Details:
Minimum Order Quantity | 1 Unit |
Model | 0-10ml |
Brand | Athena |
Display Inch | LCD |
Physical dimension and weight | 450mm x 300mm x 160mm (length x width x height), 15 Kg |
Pulse pressure | no more than 0.2MPa (Flow rate 1mL/min, pressure 5~10Mpa) |
Gradient error | No less than -3% and no more than +3% |
Maximal operating pressure | 42 MPa (flow rate 0.01~9.99mL/min), 30 MPa (flow rate 0.1~20 mL/min) |
Flow Rate Range | 0.01~9.99 mL/min(step adjustable flow rate0.01mL/min), 0.1~20 mL/min - Semi-PREP head version |
RSD | No more than +/- 0.2%, (Flow rate 1mL/min, pure water, room temp.) |
Power supply | AC (220+-22) V; frequency (50+-0.5) Hz;, AC (110+-11) V (60+-0.5) Hz (in need of switching on/off) |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | Rheodyne Injector |
Brand | Athena |
Usage/Application | Laboratory Use |
Display Inch | 0.25 |
Size | 0.25mm |
Capacity | HPLC |
Manual sample injectors have two positions, LOAD and INJECT. The LOAD position allows sample loading into the sample loop or sample chamber. A syringe is commonly used to load sample into the sample injector. After loading, manual rotation of the sample injector's handle to the INJECT position permits the flushing of loaded sample onto a column.
Details The valves listed on this page (models ending in -25) are dual mode injectors. Dual mode injectors can use both the partial-filling and the complete-filling method for loading the sample loop. They are variable volume injectors because they allow the loading of various sample volumes. These dual mode injectors, also called front-loading injectors, have a needle port for loading sample built into the handle. The unique Rheodyne injection port design allows the tip of the needle to connect directly to the sample loop for no sample loss during loading. Models with an "i" suffix are identical to the models with the same numbers, but the "i" designates a built-in position sensing switch.
We deals in Rheodyne Injector.
Specifications:
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | HPLC column heater |
Model Name/Number | ATCO-02 |
Temperature Range | 50-150 Degree Celsius |
Material | Mild Steel |
Size | 2 columns |
Model | HCO-01 |
Brand | Athena |
We offer HPLC Column Oven, that accepts varieties of column sizes. Designed in line with international quality standard, our range guarantees safe and accurate control action. These are available in various models to meet the requirements of several industry applications.
Salient Features:
Model Selection:
Features:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Model | HPLC Solvent Inlet Filter |
Application | Laboratory Use |
Brand | Athena |
Display Inch | 1/16" |
Size | 1/16" |
Temperature Zone | 5-95C |
Inlet Filters, Debubbler
HPLC Solvent Inlet FilterA 316 stainless steel tip with a Tefzel collar seals to a corrosion-resistant 316 stainless steel filter element. The slip-on filter easily attaches to the pump inlet line, without the use of wrenches. The universal 1/8" OD tip accommodates standard PTFE tubing inner diameters. The cylindrical filter is standard 10 μm porosity. Fits Altex, ISCO, LDC, Varian, Waters, PerkinElmer, and other pumps.
Disposable solvent inlet filter; 1/16" OD stem, for 1/16" ID tubing
Inlet Filter Assembly pore size 10 μm
Slip-On Inlet Filter pore size 10 μm
Stainless Steel Inlet Filter pore size 2 μm
Bottom-of-the-Bottle 2 μm Filters - These Upchurch filters have an integrated 2μm PEEK sparging frit. Connect to 1/8 inch tubing through push-on connectors.Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Application Media | HPLC Solvents |
Display | LED display |
Flow range(min-Max) | 0.002 |
Operating Pressure | 2 |
Brand | Athena |
Model | LFM |
Specification:
Features:
Specifications:
Our latest liquid flow meter has the following improvements:
Additional Information: