Our product range includes a wide range of pensky martens apparatus, flash point apparatus, pensky marten flash point apparatus, cleaveland flash and fire point apparatus, abels flash point apparatus and red wood viscometer.

Pensky Martens Apparatus

REQUEST CALLBACK

Pensky Martens Apparatus
Ask for Price

Pensky Martens Apparatus
We feel immensely pleased to offer an exclusive gamut of Pensky Martens Apparatus. The apparatus consists of test cup, lid, with handle, rotating shutter having pilot jet, stirrer with flexible shaft. It is supplied with control unit having digital temperature indicator & electronic temperature regulator. Our offered apparatus is manufactured using optimum grade components with the help of cutting-edge techniques by our adroit professionals. In order to ensure its quality, the provided apparatus is rigorously inspected on various parameters in line with set industry standards and norms.

Features:

  • Rugged construction
  • High load bearing strength
  • Anti-corrosive body

Other Details:


  • The Pen sky Marten’s Apparatus is used for determining the closed Flash Point of all Petroleum HAVING A Flash point above 48.9*C (120*F), except for out-back Bitumens. The main components of the Pen sky Martens Flash Point Apparatus are follows: Oil Cup Air Bath Electric Heating Arrangement Energy Regulator Box Top Plate Cover Assembly Having Cover Shutter Stirring Device Flame Exposure Device Thermometer Socket
  • Thermometers: IP 15C -7*c TO 100* (LOW) IP 16C 90*c TO 370*c(HIGH) Either of the thermometers may be employed if the indicated reading falls within 93* to 110*C. For tests in which the indicated reading falls within the limits –7 to 93*C (20 to 200*F), the IF 15C thermometer shall be used and for tests in which the indicated reading falls within the limits 110 to 370*C (230 to 700*F) the IP 16C thermometer shall be used. A blue print figure 1 is attached to show the constructional details. Descriptions: The brass oil cup is meant for heating the Petroleum Products to the Flash Point. It carries a mark all round in the inside to show the required level of liquid. The cup has a flange which rests on the brass top and the lower parts of the cup is within the Air Bath or Heating Vessel. The top plate is screwed on the Air Bath through brass spacers, so that an air gap is produced between the cup and the Air Bath by which the transmission to the cup is almost entirely by heated air. The cup flange has an indicator to fit correctly on the Top Plate. The heat is supplied from 220V A.C. Mains, by an electric heater kept below the Air Bath and the regulation of the heat is done by the Energy regulator. The function of the Air Bath and the Top Plate is to prevent external air droughts from interfering with the heating.
  • The cover proper of the lid is made of brass plate and has a tubular fitments which enables it to sit on the cup. The cover proper is illustrated in Figure 2 It has three holes B,A & C in the peripheral region and also one circular hole which carries a split tube for taking brass collar of a thermometer, and one central hole admits stirrer rod.
  • The peripheral hole A is larger and the flame exposure to the oil under test is given through it. The flame is produced by a burning gas jet of a gas reservoir fitted close to the hole A. The gas is supplied from gas mains.


Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Flash Point Apparatus

REQUEST CALLBACK

Flash Point Apparatus
Approx. INR 21500 / Unit
Get Best Quote

Flash Point Apparatus
By utilizing skills of our dexterous workforce, we are offering a comprehensive assortment of Flash Point Apparatus. This apparatus is used for determining the closed Flash Point of all petroleum having a flash point above 48.9*C (120*F), except for out-back Bitumen’s. We manufacture this apparatus by employing optimum quality components as well sophisticated techniques in synchronization with the defined industry standards. Owing to unique features like high functionality and durability, our offered apparatus has been able to earn a lot of popularity in the market.

Features:

  • High functioning
  • Precise design
  • Sturdy structure

The Pen sky Marten’s Apparatus is used for determining the closed Flash Point of all Petroleum HAVING A Flash point above 48.9*C (120*F), except for out-back Bitumens. The main components of the Pen sky Martens Flash Point Apparatus are follows:


  • Oil Cup
  • Air Bath
  • Electric Heating Arrangement
  • Energy Regulator Box
  • Top Plate
  • Cover Assembly Having
  • Cover
  • Shutter
  • Stirring Device
  • Flame Exposure Device
  • Thermometer Socket

Thermometers:

  • IP 15C -7 c TO 100* (LOW)
  • IP 16C 90*c TO 370*c(HIGH)
  • Either of the thermometers may be employed if the indicated reading falls within 93* to 110*C. For tests in which the indicated reading falls within the limits –7 to 93*C (20 to 200*F), the IF 15C thermometer shall be used and for tests in which the indicated reading falls within the limits 110 to 370*C (230 to 700*F) the IP 16C thermometer shall be used. A blue print figure 1 is attached to show the constructional details.
  • It is designed as per I.P. 33 and I.S. 1448 (Part I) 1960 suitable for determining the close cup flash point of petroleum products. Abel Flash Point Apparatus consist of closed Oil Cup with an internal level indicator, Stirrer, Heater, Water Bath and connecting electrical leads. A mechanically driven device for the opening of the slide and applying the ignition to the air /vapour mixture just above the sample surface is provided. It is also supplied with control unit having digital temperature indicator & electronic temperature regulator. Temperature range is from 0 to 600C. , readability 1C., sensor type J type, digital display 3 &1/2 digits, operated at 220 Volt, 50 Cycles A.C Mains




Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Pensky Marten Flash Point Apparatus

REQUEST CALLBACK

Pensky Marten Flash Point Apparatus
Approx. INR 23500 / Unit
Get Best Quote

Pensky Marten Flash Point Apparatus

Pensky–Martens closed-cup test

Standard Test Methods for Flash Point by Pensky-Martens

The Pen sky Marten’s Apparatus is used for determining the closed Flash Point of all Petroleum HAVING A Flash point above 48.9°C (120°F), except for out-back Bitumens.
The main components of the Pen sky Martens Flash Point Apparatus are follows:

· Oil Cup

· Air Bath

· Electric Heating Arrangement

· Energy Regulator Box

· Top Plate

· Cover Assembly Having

· Cover

· Shutter

· Stirring Device

· Flame Exposure Device

· Thermometer Socket

Thermometers:
IP 15C -7°c TO 100° (LOW)
IP 16C 90°c TO 370°c(HIGH)

Either of the thermometers may be employed if the indicated reading falls within 93° to 110°C. For tests in which the indicated reading falls within the limits –7 to 93°C (20 to 200°F), the IF 15C thermometer shall be used and for tests in which the indicated reading falls within the limits 110 to 370°C (230 to 700°F) the IP 16C thermometer shall be used.
A blue print figure 1 is attached to show the constructional details.

Descriptions:

The brass oil cup is meant for heating the Petroleum Products to the Flash Point. It carries a mark all round in the inside to show the required level of liquid.
The cup has a flange which rests on the brass top and the lower parts of the cup is within the Air Bath or Heating Vessel. The top plate is screwed on the Air Bath through brass spacers, so that an air gap is produced between the cup and the Air Bath by which the transmission to the cup is almost entirely by heated air. The cup flange has an indicator to fit correctly on the Top Plate. The heat is supplied from 220V A.C. Mains, by an electric heater kept below the Air Bath and the regulation of the heat is done by the Energy regulator. The function of the Air Bath and the Top Plate is to prevent external air droughts from interfering with the heating.

PENSKY-MARTENS FLASH POINT APPARATUS

 

It is designed as per I.P.34, ASTMD – 93 - 58 T and I.S. 1448 (part 1)

The apparatus consists of test cup, lid, with handle, rotating shutter having pilot jet, stirrer with flexible shaft, electrically heated with Energy Regulator control suitable to operate at 220 Volt, 50 Cycles A.C Mains. It is supplied with mercury thermometer.

 

WITH OIL TEST JET : MODEL ATFF-04 A

WITH GAS TEST JET : MODEL ATFF-04 B

Note: Motor can be fitted with flexible shaft at an extra charge.

PENSKY-MARTENS FLASH POINT APPARATUS WITH DIGITAL TEMPERATURE INDICATOR & ELECTRONIC TEMP.REGULATOR

 

It is designed as per I.P.34, ASTMD – 93 - 58 T and I.S. 1448 (part 1)

The apparatus consists of test cup, lid, with handle, rotating shutter having pilot jet, stirrer with flexible shaft. It is supplied with control unit having digital temperature indicator & electronic temperature regulator. Temperature range is from 0 to 600C. , readability 1C., sensor type J type , digital display 3 &1/2 digits, operated at 220 Volt, 50 Cycles A.C Mains

 

WITH OIL TEST JET : MODEL ATFF-05 A

WITH GAS TEST JET : MODEL ATFF-05 B

 

Note: Motor can be fitted with flexible shaft at an extra charge.



Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Cleaveland Flash and Fire Point Apparatus

REQUEST CALLBACK

Cleaveland Flash and Fire Point Apparatus
Approx. INR 21200 / Unit
Get Best Quote

Cleaveland Flash and Fire Point Apparatus

For determination of (OPEN CUP) flash & fire points of petroleum products and other liquids except fuel oils and those materials having an open cup flash below 79° C (175° F) as per specification IP 36 and IS 1448 [(P : 69) 19691.. The apparatus consists of a machined brass oil cup with handle. This rests on a heating plate which is covered with insulated board to prevent heat loss. There is a thermometer clip and test flame arrangement with swivel joint for passing over test liquid surface in the prescribed manner. Electrically operated heater is provided with temperature regulating device. Suitable to work on 220 V AC, 50 HZ mains.

Optional Accessories:


  • Thermometer IP 28C


Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Abels Flash Point Apparatus

REQUEST CALLBACK

Abels Flash Point Apparatus
Approx. INR 22500 / Unit
Get Best Quote

Able Flash Point Apparatus

Able Flash Point Apparatus ( Closed Cup ) With Digital Temp. Indicator & Regulating Unit

Able Flash Point Apparatus With Digital Temperature Indicator & Electronic Temperature Regulator

It is designed as per I.P. 33 and I.S. 1448 (Part I) 1960 suitable for determining the close cup flash point of petroleum products.

Abel Flash Point Apparatus consist of closed Oil Cup with an internal level indicator, Stirrer, Heater, Water Bath and connecting electrical leads. A mechanically driven device for the opening of the slide and applying the ignition to the air /vapour mixture just above the sample surface is provided. It is also supplied with control unit having digital temperature indicator & electronic temperature regulator. Temperature range is from 0 to 600C. , readability 1C., sensor type J type, digital display 3 &1/2 digits, operated at 220 Volt, 50 Cycles A.C Mains

Abels Flash Point Apparatus

For determination of (close cup) Flash Point of petroleum products & mixtures above 19° C and below 70°C or according to IP 33 and IP 170 and also IS 1448 (Part 1)1985 (P : 20). The apparatus consists of Brass/ Gun metal machined Cup Cover fitted with shutter mechanism, test flame arrangement (oil test jet / gas test jet), stirrer & thermometer Socket. The assembly rests in double Jacketed Copper/SS water bath. A funnel, an overflow pipe and split thermometer socket are fitted on top of the heating bath. The outer jacket of Bath is fitted with a stand. An electric heater with energy control is provided at the bottom with flexible cord.


Optional Accessories:

 

  • Digital temperature controller and indicator
  • Thermometer IP 74C having wide range
  • Thermometer IP 75C having wide range


Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Oil and Petroleum Testing Equipment

REQUEST CALLBACK

Oil and Petroleum Testing Equipment
Approx. INR 22999 / Unit
Get Best Quote

Oil And Petroleum Testing Equipments
Our product range includes a wide range of Oil And Petroleum Testing Equipments such as Pensky Marten Flash Point Apparatus, Abels Flash Point Apparatus, Red Wood Viscometer, Drop Point Apparatus, Penetrometer Apparatus, Saybolt Viscometer Apparatus and many more items.

ATFF-01

Abel Flash Point Apparatus

 

A. With Oil Test Jet

 

B. With Gas Test Jet

ATFF-02

Abel Flash Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator

 

A. With Oil Test Jet

 

B. With Gas Test Jet

ATFF-03

Continuously Variable Temp. Control For Above Unit

ATFF-04

Pensky Martens Flash Point Apparatus

 

A. With Oil Test Jet

 

B. With Gas Test Jet

ATFF-05

Pensky Martens Flash Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator

 

A. With Oil Test Jet

 

B. With Gas Test Jet

ATFF-06

Stirrer Motor With Flexible Shaft For Above Unit

ATFF-07

Continuously Variable Temp. Control For Above Unit

ATFF-08

Cleavland Flash Point & Fire Point Apparatus

ATFF-09

Cleavland Flash Point & Fire Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator

ATFF-10

Cloud And Pour Point Apparatus (Double Wall)S.S.

 

For Single Test

 

For Four Test

ATFF-11

Softening Point Apparatus It Is Supplied With Thermometer I.P.61° C

ATFF-12

Cone Penetrometer Apparatus

ATFF-13

Penetrometer As Per Is: 2720 (Part-V)

ATFF-14

Drop Point Apparatus

ATFF-15

Stirring Motor With Flexible Shaft For Above Unit



Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Cloud and Pour Point Apparatus

REQUEST CALLBACK

Cloud and Pour Point Apparatus
Approx. INR 19500 / Unit
Get Best Quote

Cloud and Pour Point Apparatus

This is made according to specifications laid by IP 15 and IS 1448 (P: 10) 1970. The pour point is the lowest temperature at which the oil will just fail to flow. The apparatus consists of main cooling bath made of SS Sheet, stand unit with drain plug & cover with provision for fitting thermometer & for adding freezing mixture. A glass jar for holding oil is provided with metallic Jar. The instrument is supplied with insulated body. These are available in three sizes: - Single Test, Four Test, and Six Test Model with insulated outer body. The refrigeration Model also available to test the oil sample up to -30° C range.

Optional Accessories:

  • Thermometer IP 1C (Low Range)
  • Thermometer IP 2C ( Medium Range)


Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Pensky Martens Closed Cup Flash Point Tester

REQUEST CALLBACK

Pensky Martens Closed Cup Flash Point Tester
Approx. INR 19500 / Unit
Get Best Quote

Pensky-Martens Closed Cup Flash Point Tester

Brief description:This instrument is manufactured as per standards GB/T 261-2008 Determination of Flash Point(Pensky-martens Closed Cup) and ASTM D93. It is suitable to make determination of the closed cup flash point of the petroleum products which flash point over 40.

Main technical features

  1. This instrument is designed correspond with the requirements of GB/T261-2008.
  2. The heating power is continuously and stepless adjustable. The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
  3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
  4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting units.

Main technical specifications and parameters

  • Power supplyAC (220±10%)V, 50Hz.
  • Heating device:The heating power is continuously adjustable from 0 W to 600W.
  • Rate of sample’s heating up:(112)/minControllable and adjustable.

Electric stirring rate

  1. (90120)turns/min, suitable to test procedure
  2. (250±10)turns/min,suitable to test procedure

Standard oil cup

  1. Inner diameter: 50.7mm50.8mm.
  2. Depth: 55.7mm56.0mm.
  3. The scribed line depth of capacity of testing oil: 33.9mm34.3mm.
  4. Capacity of testing oil:about 70ml.

Igniting device

  1. Igniting source: gasor other civilian fuels the same below
  2. Bore diameter: 0.8mm


Additional Information:

  • Minimum Order Quantity: 1 Unit
Yes! I am Interested

Red Wood Viscometer

Red Wood Viscometer

Additional Information:

  • Minimum Order Quantity: 1 Unit
  • Approx. INR 19999 / Unit
    Yes! I am Interested



     
    X


    Call Us:  +91-8079449747
    Athena Technology
    Mrs. Milan Salunke (Director)
    802, Hercules, Lodha Paradise Complex, Majiwada, Near Majiwada Flyover Thane West,
    Thane - 400601, Maharashtra, India
    Contact via E-mail
    Contact via SMS



    Home  |   About Us   |  Products  |  Site Map  |   Contact Us   |   Mobile Site

    © Athena Technology. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Athena Technology